The control unit of the GROHE Blue
®
fitting is set for operation
with the 600 liter filter cartridge at the factory.
For operation with other filter cartridges the control unit must be
set out.
Setting filter size, see fold-out page II, Fig. [7].
U button for filter size selection:
• Press and hold U button once until the currently setted
value (e. g. F1) flashes in the display
• Press the U button and select the required value appears
- F4: 600 liters 40 404 001
- F5: 1,500 liters 40 430 001
- F6: 3,000 liters 40 412 001
- F7: 600 liters 40 691 001 (Magnesium)
- F8: 3.000 liters 40 547 001 (Activ carbon)
Press and hold the U button until the required value stops
flashing
• Release the U button:
The remaining filter capacity is displayed.
The fitting is now fully installed and ready for operation.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page II, Fig. [7].
button for filter replacement reset:
• Press and hold button until rF flashes in the display.
• Release the button and press again until rF stops
flashing.
• Release the button.
The remaining filter capacity is reset and then displayed
again.
Warning
Risk of damage:
Always disconnect the power supply before performing
maintenance work on the system. The plug-in connectors
can then be disconnected, see fold-out page II, Fig. [7].
Inspect and clean all components and replace if necessary.
I. Mousseur (13 199), see fold-out page I.
Assemble in reverse order.
II. Solenoid valve (42 390), see fold-out page I.
Assemble in reverse order.
Service
Note the Fault / Cause / Remedy table for information on
eliminating problems.
If EE flashes or the problem cannot be rectified, interrupt the
power supply and consult a specialist installer or contact the
GROHE Service Hotline via email under TechnicalSupport-
Replacement parts
See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Environment and recycling
Used filter cartridges can be disposed of hazard-free in
domestic waste.
Fault Cause Remedy
Filtered water not
flowing
Water supply interrupted
Solenoid valve defective
Plug-in connector of solenoid valve
without contact
- Open shut-off valves
- Replace solenoid valve
- Attach plug-in connector
No filtered water,
Blue
®
handle flashes
red, E4 in the display
Fitting and control unit not synchronized - Synchronise with one another, see section
Installation
No filtered water,
Blue
®
handle flashes
red, E6 in the display
Values range does not concur - Synchronise with one another, see section
Installation
E7, E8 in the display Filter capacity exceeded - Change filter cartridge immediately
Indicator lamps
do not flash/flash
continuously
Control not recognised - With mains plug connected, disconnect plug-in
connector, wait 30 seconds and reconnect