GROHE 31346DC1 Service Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
5
Connect plug-in connection between fitting and cooler/
carbonator, see Fig. [6].
Establish voltage supply via mains plug, see Fig. [7].
The display illuminates and the remaining filter capacity is
displayed in percent.
Connect CO
2
cylinder, see Figs. [8] to [13].
Do not operate the valve on the back of the cooler/
carbonator as otherwise CO
2
will escape, see Fig. [9].
- The valve is only needed when cleaning the cooler/
carbonator.
The fitting has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
The display in the handle illuminates blue.
If the Blue
®
handle is flashing red and E4 or E6 appears in
the display, the fitting and cooler/carbonator must be
synchronised as follows, see Fig. [14]:
Press and hold the and buttons simultaneously until SE
flashes in the display.
• Press the button until SE stops flashing.
• Release the button, C- flashes in the display.
Keep pressing the U or button until H- flashes in the
display.
• Press the button until H- stops flashing.
• Blue
®
handle synchronisation starts; HC appears in the
display and the Blue
®
handle lights up red.
As soon as the Blue
®
handle lights up green, open the fitting
fully by turning the Blue
®
handle.
As soon as the Blue
®
handle briefly flashes green, close the
fitting by turning the Blue
®
handle, HC flashes in the display.
Confirm the setting by pressing the button longer, HC
appears.
• Release the button.
The remaining filter capacity is displayed.
Commissioning
Control, see fold-out page II, Fig. [14].
The buttons have the following functions:
Filter replacement reset
U Filter size selection
Carbonate hardness adjustment
Display, see Fig. [14].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator, see Fig. [15].
Set the filter size, see Fig. [14] and [16].
U button for filter size selection:
• Press and hold U button once until the currently setted
value (e. g. F1) flashes in the display
• Press the U button and select the required value appears
- F1: 40 404 000
- F2: 40 430 000
- F3: 40 412 000
- F4: 40 404 001
- F5: 40 430 001
- F6: 40 412 001
- F7: 40 691 001 (Magnesium)
- F8: 40 547 001 (Activ carbon)
Press and hold the U button until the required value stops
flashing
• Release the U button:
The remaining filter capacity is displayed.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Set carbonate hardness at filter head, see Fig. [16].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page III.
Display and setting of carbonate hardness on cooler/
carbonator, see table column B on fold-out page III and
Fig. [14].
button for carbonate hardness adjustment:
Press and hold the button once until the currently setted
value (e. g. C3) flashes in the display
• Press the button and select the required value:
- C4: carbonate hardness
9(bypass 3)
- Factory setting:
C3: carbonate hardness 10 - 24 (bypass 2)
- C2: carbonate hardness 25 - 29 (bypass1)
- C1: carbonate hardness
30 (bypass 0)
Press and hold the button until the setted value stops
flashing
• Release the button.
The remaining filter capacity is displayed.
The liter capacity of the filter cartridge varies according to the
water hardness set and the size of the filter cartridge, see table
on fold-out page III.
The cooler/carbonator is set for operation with the 600 litre
filter cartridge (Prod no.: 40 404 001) at the factory.
For operation with other filter cartridges the cooler/carbonator
must be set out.
The fitting with cooler/carbonator is now fully installed and
ready for operation.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page II, Fig. [14].
button for filter replacement reset:
Press and hold button until rF flashes in the display.
• Release the button and press again until rF stops
flashing.
• Release the button.
The remaining filter capacity is reset and then displayed
again.
Restore factory settings, see Fig. [14].
Reset U buttons to factory settings:
Press and hold the U buttons simultaneously until PA
starts flashing in the display.
Release the U buttons.
The remaining filter capacity is displayed.
Important:
Risk of damage!
Always disconnect the power supply and interrupt
the CO
2
supply before carrying out maintenance work
on the system. The plug-in connector can then be
disconnected, see fold-out page II, Figs. [6] and [7].
Inspect and clean all components and replace if necessary.
Assemble in reverse order.