Cleaning cooler/carbonator
For hygienic and healthy reasons, the cooler/carbonator
must be cleaned once a year. Cleaning must be
performed before changing the filter cartridge, in order to
prevent contamination of the replacement filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434 001) and the
accompanying adapter (Prod. no.: 40 694 000 or 40 699 000)
could be ordered at www.grohe.com.
Service
Note the Fault/ Cause/ Remedy table for information on
eliminating problems.
If EE flashes or the problem cannot be rectified, interrupt the
power supply to the cooler/carbonator. Note down the serial
number of the cooler/carbonator on the rear of the device and
consult a specialist installer or contact the GROHE Service
Hotline via email under T[email protected].
The GROHE Blue
®
Chilled cooler/carbonator may only be
repaired by GROHE Service.
Environment and recycling
Used filter cartridges can be disposed of hazard-free in
domestic waste.
The accompanying CO
2
cylinder can be refilled locally.
The CO
2
cylinder must not be sent back. At the end of its
useful life it must be disposed of locally in accordance with the
applicable regulations.
Note: A 2 kg CO
2
cylinder (Prod. no: 40 423 000) can be
ordered at www.grohe.com.
The cooler/carbonator is an electrical device, to which return
and take-back obligations apply in many countries. GROHE
participates in such take-back systems in all relevant
countries.
This category of device does not belong in
the domestic waste, but must be disposed of
separately in accordance with the relevant
local national regulations.
Fault Cause Remedy
Water not flowing Water supply interrupted - Open shut-off valves
No filtered water,
Blue
®
handle flashes
red, E1 in the display
Safety shut-off of pump - Open shut-off valves
- Disconnect mains supply, wait 30 seconds and
reconnect
No filtered water, E2
in the display
Exceeding the drawing time
- Close Blue
®
handle
No filtered water, E3
in the display
No connection between fitting and
cooler/carbonator
Cable or connector faulty
- Connect plug-in connector
- Contact GROHE Service
No filtered water,
Blue
®
handle flashes
red, E4 in the display
Fitting and cooler/carbonator not
synchronized
- Synchronise with one another, see section
Installation
No filtered water,
Blue
®
handle flashes
red, E5 in the display
Fault function of cooler/carbonator - Connect mains supply, wait 30 seconds and
reconnect
No filtered water,
Blue
®
handle flashes
red, E6 in the display
Values range does not concur - Synchronise with one another, see section
Installation
No filtered water, E7
in the display
Fault function of cooler/carbonator - Connect mains supply, wait 30 seconds and
reconnect
Blue
®
handle flashes
orange, E8 in the
display
Filter capacity exceeded - Change filter cartridge immediately
E9 flashes alternately
with HI in the display
cooler/carbonator overheated
- Close Blue
®
handle, ensure ventilation and reduce
ambient temperature to max. 50 °F
- Disconnect mains supply, wait 30 seconds and
reconnect
No carbon dioxide in
positions Medium
and Sparkling
•CO
2
cylinder not opened or empty - Fully open valve of CO
2
cylinder or replace
cylinder